<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-16 17-19-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 37 dBuV YLEX
Pilot RDS Phase Difference
7.4 kHz 2.4 kHz 61 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 61 kHz 13879 0,0144
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,9 dBr 3,44 dBr 4,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 17:19, 16.01.2026
RT
"YleX T back: Womma Seppälä "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 61 kHz MIN: 16 kHz % above 76 kHz: 0,0144 Acquired: 2026/01/16 17.18.44 Total samples: 13879 Equivalent time: 0:11:33 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 4,9 dBr MIN: 0,9 dBr AVE: 3,44 dBr % above 12,2 dBr: 0,0 Last value: 4,4 dBr (2026/01/16 17.18.44) 17.04 17.06 17.08 17.10 17.12 17.14 17.16 17.18 0 2 4 Pm [dBr]